Table R301.2(1). CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

GROUND SNOW LOADo

WIND DESIGN

SEISMIC DESIGN CATEGORYf

SUBJECT TO DAMAGE FROM

Speedd (mph)

Topographic effectsk

Special wind regionl

Wind-borne debris zonem

Weatheringa

Frost line depthb

Termitec

ZERO

85

NO

NO

NO

D2 or E

NEGLIGIBLE

N/A

VERY HEAVY

ICE BARRIER UNDERLAYMENT REQUIREDh

FLOOD HAZARDSg

AIR FREEZING INDEXi

MEAN ANNUAL TEMPj

NO

See Footnote ‘p’

ZERO

57.2°F

MANUAL J DESIGN CRITERIAn

Elevation

Altitude correction factor e

Coincident wet bulb

Indoor winter design relative humidity

Indoor winter design dry-bulb temperature

Outdoor winter design dry-bulb temperature

Heating temperature difference

345

N/A

63

N/A

70

40

30

Latitude

Daily range

Indoor summer design relative humidity

Summer Design Grains

Indoor summer design dry-bulb temperature

Outdoor summer design dry-bulb temperature

Cooling temperature difference

38

16

50

-6

75

80

5

For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.

a.Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this Code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2.(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652.

b.Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade.

c.The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage.

d.The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map Figure R301.2(2). Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.

e.The jurisdiction shall fill in this section of the table to establish the design criteria using Table 10A from ACCA Manual J or established criteria determined by the jurisdiction.

f.The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1.

g.The jurisdiction shall fill in this part of the table with: the date of the jurisdiction’s entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); and the title and date of the currently effective Flood Insurance Study or other flood hazard study and maps adopted by the authority having jurisdiction, as amended.

h.In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO."

i.The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index--USA Method (Base 32°)".

j.The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index--USA Method (Base 32°F)".

k.In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

l.In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

m.In accordance with Section R301.2.1.2, the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table.

n.The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction.

o.The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figures R301.2(3) and R301.2(4).

p.Flood Hazard Data for the City of Berkeley:

Date of Jurisdiction’s Entry into the NFIP: December 7, 1973;

Date of adoption of the first code or ordinance for management of flood hazards: Ordinance No. 5085-N.S., July 25, 1978;

Date of Flood Insurance study: Aug 3, 2009;

Panel numbers and dates of all currently effective maps adopted by the AHJ (Ordinance 7108-NS 9/29/09):

FEMA’s "Use of Digital Flood Hazard Data" establishes that paper and digital maps are equivalent. Policy and related information are available from FEMA. The policy implements section 107 of Public Law 108-264, 118 Stat. 724 (2004)

Panel 13 (not available in printed form)

Panel 14 of 725, Map Number 06001C0014G, August 3, 2009

Panel 18 of 725, Map Number 06001C0018G, August 3, 2009

Panel 19 of 725, Map Number 06001C0019G, August 3, 2009

Panel 38 (not available in printed form)

Panel 51 (not available in printed form)

Panel 52 of 725, Map Number 06001C0052G, August 3, 2009

Panel 53 (not available in printed form)

Panel 54 of 725, Map Number 06001C0054G, August 3, 2009

Panel 56 of 725, Map Number 06001C0056G, August 3, 2009

Panel 57 of 725, Map Number 06001C0057G, August 3, 2009

Panel 80 of 725, Map Number 06001C0080G, August 3, 2009

(Ord. 7839-NS § 2, 2022)